Every access-controlled door has a fail state: what it does when power is lost. It is a small phrase on a spec sheet and one of the most consequential decisions in the entire system — and on a lot of installs, nobody made it deliberately.
The two states
Fail-safe means the door unlocks when power is lost. The lock requires power to stay locked. Safety of people is prioritized over security of property.
Fail-secure means the door stays locked when power is lost. The lock requires power to release. Security of property is prioritized.
Neither is universally correct. The right answer varies per door, which is exactly why a door schedule should state it for every opening.
What code decides for you
On egress paths, this is not a preference. NFPA 101 requires that occupants can always exit, so doors on a required means of egress must permit free egress regardless of power state and must release on fire alarm. Magnetic locks in particular are scrutinized because they physically hold a door shut — they must release on alarm and on power loss, and delayed-egress arrangements need specific approval.
Note the distinction that trips people up: free egress is required. Free entry is not. A door can stay locked from the outside during a power failure while still opening from the inside — and mechanical hardware handles the inside half without needing power at all.
Where fail-secure is usually right
- Server and IT rooms. A power outage should not fling open the room with your infrastructure in it. Interior doors like this are not egress paths from the building.
- Records and medication storage. Same logic, with a compliance dimension — an outage should not create an unlogged open door to protected information.
- Stockrooms and cash areas. Property protection, no egress role.
- Exterior entry doors in most configurations — locked from outside, always openable from inside via mechanical hardware.
Where fail-safe is required or sensible
- Any door on a required egress path where the locking device would impede exit.
- Stairwell doors in many configurations, which have their own re-entry requirements.
- Doors held by magnetic locks — these must release, without exception.
The battery question people forget
Fail-secure doors stay locked during an outage, which is the intent — but if the reader and controller are also dead, nobody can badge in either. For rooms people need access to during an outage, the controller needs battery backup. That is a design decision made at install, not something you discover during your first extended power failure.
How to check what you have
Ask your installer for the door schedule and look for the fail state on each opening. If no such document exists, that is the finding. On an existing system you can test carefully with the fire panel during a scheduled inspection — but do not experiment with egress hardware informally.
Why this ends up wrong so often
Because it is invisible until it matters. A system installed with every door defaulted to whatever the hardware shipped as will operate normally for years, and reveal itself during the one outage or alarm when behavior suddenly counts. Deciding deliberately costs nothing at install.
We document the fail state of every opening as standard — see access control installation, or call (833) 306-3168 if you want an existing system reviewed.